APC Back-UPS Pro 1500VA (BR1500G)
The official replacement cartridge for the BR1500G is APCRBC124, the same 24 V, 9 Ah cartridge used in the BX1500M. Confirm the label; a BR1500MS2 uses a different SKU.
Official replacement cartridge
APCRBC124
| Official SKU | APCRBC124 |
|---|---|
| Voltage | 24 V |
| Capacity | 9 Ah |
| Type | Lead-acid |
| Cartridge quantity | 1 |
| Cartridge warranty | 2-year repair or replace |
Official APCRBC124 product page
UPS specifications (from the official datasheet or product page)
| Family / product name | APC Back-UPS Pro 1500VA (BR1500G) |
|---|---|
| VA rating | 1500 VA |
| Watt rating | 865 W |
| Topology | Line interactive |
| Waveform | Stepped approximation to a sine wave |
| Input voltage | 120 V AC, 1 phase |
| Form factor | Tower |
| Outlets | 10 × NEMA 5-15R (5 battery + surge, 5 surge-only) |
| Transfer time | 8 ms typical, 12 ms maximum |
| Typical recharge time | 8 hours (typical) |
| Typical battery life | 3–5 years |
| UPS battery voltage | 24 V |
| UPS battery capacity | 9.0 Ah |
| Official RBC quantity | 1 |
| User-replaceable battery | Yes (datasheet title and official table: user-replaceable battery) |
| UPS warranty (as published) | 36 months (UPS), 12 months (battery supplied with the UPS) |
| Equipment protection policy | Lifetime: $150,000 |
Related models
- BR1300G: Schneider’s BR1300G/BR1500G troubleshooting FAQ also tells you to replace the battery with APCRBC124.
- BR1500MS2: The official USA/Canada table lists APCRBC163 for BR1500MS2 — not APCRBC124.
How to replace the battery
Schneider’s official “G” family battery-install video covers BR1500G and points to APCRBC124. Typical recharge on this model is 8 hours, which is shorter than the 16 hours listed for the BX1500M.
Official installation video: https://www.se.com/us/en/faqs/FA158954/
- Confirm the label says BR1500G, not BR1500MS2 or BR1500MS.
- Follow Schneider’s official Back-UPS XS/RS “G” installation video and the APCRBC124 instruction sheet.
- If the unit recently ran on battery, the official troubleshooting FAQ says to charge it for 16 hours before concluding the battery has reached end of life.
- Install the complete APCRBC124 cartridge and recycle the used pack.
These are orientation steps, not a substitute for the manufacturer’s instruction sheet. Lead-acid UPS batteries can present electrical and chemical hazards.
Warranty considerations
- A separately purchased APCRBC124 carries a 2-year repair-or-replace warranty. The BR1500G datasheet lists 12 months of battery coverage on the pack that shipped with the UPS.
- Using a non-APC battery will void APC’s Equipment Protection Policy (FAQ FA328895). This datasheet lists that policy at a lifetime $150,000.
When to replace the whole UPS instead
- If a new genuine APCRBC124 and a full charge do not clear the replace-battery indicator, the UPS may need to be replaced.
- Like other Back-UPS Pro “G” units, the BR1500G uses a stepped approximation to a sine wave. Active-PFC power supplies sometimes need a true sine-wave UPS instead.
Where to buy (affiliate placeholders)
These are ordinary search links, not tracked affiliate tags. When a program is joined, replace the href and keep the data-affiliate attribute.
Search Amazon for APC APCRBC124 Affiliate placeholderSearch eBay for APC APCRBC124 Affiliate placeholder
FAQ
Does the BR1500G use the same battery as the BX1500M?
Yes. Official Schneider sources list APCRBC124 for both. The UPS ratings are not identical (this datasheet is 1500 VA / 865 W with an 8-hour typical recharge; the BX1500M datasheet is 1500 VA / 900 W with a 16-hour typical recharge).
My unit says BR1500MS2. Can I use APCRBC124?
Not according to Schneider’s official table, which lists APCRBC163 for BR1500MS2. Order from the label on your UPS.
Sources
- APC BR1500G product datasheet (APCRBC124, 24 V, 9.0 Ah, 8-hour typical recharge)
- Official USA/Canada Back-UPS replacement battery table (BR1500G = APCRBC124)
- BR1300G / BR1500G troubleshooting (replace battery with APCRBC124)
- APCRBC124 official product page
- Back-UPS XS/RS “G” battery installation video
- Why use only a genuine APC RBC