APC

APC Back-UPS 1350, Compact Tower, 1350VA, 120V, AVR, LCD (BX1350M)

The official USA/Canada replacement cartridge for the BX1350M is APCRBC123, a 24 V, 7 Ah lead-acid cartridge with a 2-year repair-or-replace warranty. It is not the same cartridge as its BX-series siblings.

Official replacement cartridge

APCRBC123

Official SKUAPCRBC123
Voltage24 V
Capacity7 Ah
TypeLead-acid
Cartridge quantity1
Cartridge warranty2-year repair or replace
Assembly7 Ah, 24 Vdc replaceable battery for APC Back-UPS and Smart-UPS line-interactive units

Official APCRBC123 product page

UPS specifications (from the official datasheet or product page)

Family / product nameAPC Back-UPS 1350, Compact Tower, 1350VA, 120V, AVR, LCD (BX1350M)
VA rating1350 VA
Watt rating810 W
Input voltage120 V
Form factorCompact tower
Outlets10 × NEMA outlets (5 surge-only, per the official product name)
Official RBC quantity1
User-replaceable batteryYes (official Back-UPS table: user-replaceable battery)

Related models

How to replace the battery

Schneider publishes an instruction sheet with the APCRBC123 cartridge and a user guide for the BX1350M (both linked from the official product pages). Follow those official documents.

  1. Confirm the rear or bottom label says BX1350M. Close relatives use different official SKUs: BX1500M uses APCRBC124, BX1000M uses APCRBC158, and BX850M uses RBC17.
  2. If backup time is short right after an outage, Schneider’s BX troubleshooting FAQ says to charge the battery cartridge for 16 hours before deciding it has reached end of life.
  3. Read the BX1350M user guide and the APCRBC123 instruction sheet from the official product pages before opening the battery compartment.
  4. Install the complete APCRBC123 cartridge as a unit. Recycle the used pack (the official cartridge page notes support for APC-authorized recycling).
  5. After a full charge, check that the REPLACE BATTERY indicator has cleared.

These are orientation steps, not a substitute for the manufacturer’s instruction sheet. Lead-acid UPS batteries can present electrical and chemical hazards.

Warranty considerations

Genuine vs third-party packs. This guide lists only the official manufacturer cartridge. Third-party kits are widely sold, but this site does not verify their dimensions, runtime, or safety against the OEM specification. Schneider Electric’s FAQ on genuine APC RBCs states that a non-APC battery may result in lower runtime, damage the UPS, create hazardous conditions, or void safety certifications, and that it will void APC’s Equipment Protection Policy. If you still consider an aftermarket pack, treat voltage, capacity, and physical fit as necessary starting points — not as proof of compatibility — and expect warranty terms to change.

When to replace the whole UPS instead

Where to buy (affiliate placeholders)

These are ordinary search links, not tracked affiliate tags. When a program is joined, replace the href and keep the data-affiliate attribute.

Search Amazon for APC APCRBC123 Affiliate placeholderSearch eBay for APC APCRBC123 Affiliate placeholder

Affiliate disclosure

FAQ

What battery does a BX1350M take?

Schneider Electric’s official USA/Canada Back-UPS table and the BX850M/BX1000M/BX1350M/BX1500M troubleshooting FAQ both list APCRBC123. The official APCRBC123 page describes it as a 24 V, 7 Ah lead-acid cartridge with a 2-year repair-or-replace warranty.

Can I use the BX1500M battery (APCRBC124) instead?

No. Schneider assigns APCRBC124 (24 V, 9 Ah) to the BX1500M and APCRBC123 (24 V, 7 Ah) to the BX1350M. Order the SKU listed for your exact model.

Is the BX1350M battery user-replaceable?

Yes. Schneider’s official USA/Canada table marks the BX1350M as a user-replaceable battery.